Detection of switches for household and similar purposes

 news    |      2024-01-12 09:34:02

How to process the testing report? What are the testing items and standards? Today, the editor of Baijian Testing will take you to understand the specific tests required for the relevant testing business. At the same time, Baijian can also design testing plans based on corresponding testing standards or according to your needs

Report qualifications: CNAS, CMA, CAL, etc.

Testing costs: quoted based on customer needs and experimental complexity

Sample size: selected for sending or visiting based on sample size

Display style: electronic version

Testing cycle: 3-15 working days (urgent)

Testing items:

Dielectric performance, size inspection, mechanical and electrical life test, mechanical strength, marking, normal operation, temperature rise, electric shock protection test.

, Electrical strength, insulation resistance, heat resistance, resistance to abnormal heat and combustion, resistance to abnormal heat and combustion (burning wire test), tripping characteristic test, breaking capacity, anti electric shock protection, rated value, marking, size inspection, insulation material's resistance to abnormal heat and combustion, insulation resistance and electrical strength, rust prevention performance, screws, current carrying parts and connections, classification, terminals/terminals and heads, insulation material's resistance to abnormal heat, combustion and leakage marks, aging and leakage resistance Protection and moisture resistance, rust/rust resistance, screws, current carrying components and connections, electrical clearances, creepage distance, durability of markings, operating characteristics provided by the casing

Testing standards:

1. Residual current operated circuit breakers (RCBOs) with overcurrent protection for household and similar purposes - Part 1: General rules GB16917.1-2014, Article 9.3

2 GB 2099.1-2008 "Plug and socket outlets for household and similar purposes - Part 1: General requirements" GB 2099.1-2008 Article 8

3. B "Residual current operated circuit breakers (RCO) with overcurrent protection for household and similar purposes - Part 1: General rules" G16917.1-2014 Article 8.1.3 Appendix

4. GB/T 16915.1-2014 GB/T 16915.1-2014 "Switches for fixed electrical installations for household and similar purposes - Part 1: General requirements" 8, 9

5 GB/T 16915.1-2014 "Switches for household and similar fixed electrical installations - Part 1: General requirements" 9

6. GB/T 10963.1-2005 "Electrical accessories - Overcurrent protection circuit breakers for household and similar installations - Part 1: Circuit breakers for AC use" 9.7

7. GB/T 2099.1-2008 Household and similar plug and socket outlets - Part 1: General requirements GB/T 2099.1-2008

8 GB/T 16915.1-2014 Switches for household and similar fixed electrical installations Part 1: General requirements GB/T 16915.1-2014

9, GB/T 2099.1-2008 Household and similar plug and socket Part 1: General requirements 24

10, GB 16915.1-2014 "Switches for household and similar fixed electrical installations Part 1: General requirements" GB16915.1-2014 Article 8

Testing process steps

1. Telephone communication Confirm requirements 2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is required