Where is the overlay test going? BAIJIAN can provide coverage layer testing services, third-party, high-tech enterprises, CMA qualification certification institutions, complete testing instruments, strong scientific research teams, mainly engaged in industrial diagnosis, material composition testing, material quality testing, material performance testing and other services. Inspection reports can be issued within 7-15 working days, support scanning to check authenticity, and provide nationwide on-site sampling and sample sending testing services. The testing cycle is short, the testing cost is low, and the testing data is scientific and accurate p>
Test cycle: 7-15 working days
Test cost: Free initial inspection. After the initial inspection, a quotation will be provided based on the customer's testing needs and the complexity of the experiment.
p> Covering layer test scope: Automotive component covering layer, metal covering layer, enamel covering layer, rubber electroplating covering layer, anode and cathode covering layer, tire covering layer, mechanical surface covering layer, conveyor belt covering layer, steel wire covering layer, casting substrate covering layer, etc p> Covering layer test items: Salt spray test: Acetic acid salt spray test (ASS test), neutral salt spray test (NSS test), copper accelerated acetate spray test, etc p> Other: Vickers microhardness test, porosity test, wear test, full immersion corrosion test, impact test, hundred grid test, thickness test, adhesion test, shear wave test, failure analysis, etc p> If you have any other needs, please contact the laboratory engineer and we will provide you with one-on-one answers p> What are the functions of the BAIJIAN test report? What problems can I help you solve< p> 1. Sales use. (Selling one's own products and issuing third-party testing reports to make customers trust their product quality more)2. Industrial problem diagnosis and use. (When encountering some tricky problems, solve them by testing report data)
3. Improve product quality. (By comparing the testing data, identify the problems with one's own product, improve product quality, and reduce production costs)
4. Use of research paper data p> 5. Product import and export use. (Testing report from Baijian.com, supporting scanning code to distinguish authenticity!)
Coating test standardGB/T 3138-2015 Terminology for surface treatment of metal and other inorganic coatings
GB/T 4955-2005 Measurement of coating thickness of metal coatings Anodic dissolution Coulomb method
GB/T 4956-2003 Measurement of coating thickness of non-magnetic coatings on magnetic substrates Magnetic method
GB/T 4957-2003 Measurement of coating thickness of non-conductive coatings on non-magnetic substrates Eddy current methodGB/T 5270-2005 Evaluation of testing methods for adhesion strength of metal coatings electrodeposition and chemical deposition on metal substrates
GB/T 5770-2005 53-2013 Steel Wire Rope Core Conveyor Belt - Determination of Total Thickness and Cover Layer Thickness
GB/T 5756-2009 Conveyor Belt Terminology and Definitions
GB/T 6461-2002 Metal and Other Inorganic Coverings on Metal Substrates - Rating of Samples and Specimens after Corrosion Testing
GB/T 6462-2005 Microscopic Method for Measuring Metal and Oxide Cover Layer Thickness
GB/T 6463-2005 Review of Measurement Methods for Metal and Other Inorganic Cover Layer Thickness
GB/T 6465-2008 Corrosion Paste Corrosion Test (Corr Test)
GB/T 9789-2008 Sulfur dioxide corrosion test for metallic and other inorganic coatings under normal condensation conditions
GB/T 9790-1988 Metallic coatings and other related coatings Vickers and Knoop microhardness tests
GB/T 9793-2012 Thermal sprayed metallic and other inorganic coatings Zinc Aluminum and its alloys
GB/T 9797-2005 Metal coatings - Nickel chromium and copper nickel chromium electroplated coatings
GB/T 11375-1999 Metal and other inorganic coatings - Safety during thermal spraying operations
GB/T 11376-2020 Phosphating coatings on metal and other inorganic coatings - General rules for corrosion testing of metal and other inorganic coatings under storage conditions
GB/T 11379-2008 Metal coatings - Chromium electroplated coatings for engineering purposes
GB/T 12305.6-1997 Test methods for metal coatings - Gold and gold alloy electroplated coatings - Part 6: Determination of residual salts
GB/T 12599-2002 Technical Specifications and Test Methods for Tin Electroplated Coatings on Metal Coatings
GB/T 13322-1991 Low Hydrogen Embrittlement Cadmium Titanium Electroplated Coatings on Metal Coatings
GB/T 13346-2012 Cadmium Electroplated Coatings on Metal and Other Inorganic Coatings on Steel After Treatment
GB/T 13912-2002 Technical Requirements and Test Methods for Hot Dip Galvanized Coatings on Steel Parts
GB/T 13912-2020 Technical Requirements and Tests for Hot Dip Galvanized Coatings on Steel Parts Test MethodGB/T 15821-1995 Measurement Method for Ductility of Metal Coverings
GB/T 16745-1997 Standard Test Method for Brazing of Metal Covering Products
GB/T 16921-2005 Measurement of Metal Covering Layer Thickness X-ray Spectroscopy
GB/T 17044-2013 Steel Wire Rope Core Conveyor Belt Covering Layer and Core Layer Adhesion Strength Test
GB/T 17720-1999 Porosity Test of Metal Covering Layer Review
GB/T 17721-1999 Porosity Test of Metal Covering Layer Ferrous Reagent Test
GB/T 17722-1999 Scanning Electron Microscopy Measurement Method for Gold Covering Layer Thickness
GB/T 18179-2000 Metal Coatings - Porosity Test - Wet Sulfur (Sulfur Hua) TestWhat are the advantages of using a hundred inspection net for testing?? Why choose BAIJIAN< p> 1. BAIJIAN is a collectively owned testing institution p> 2. Free initial inspection, no testing fees will be charged during the initial inspection period p> 3. Multiple laboratory branches across the country support on-site sampling/sample testing p> 4. Short detection cycle, high detection cost, and complete experimental plan p> 5. Complete qualifications, complete laboratory instruments, and a strong research team p>6. 36 languages support writing MSDS services
The above is an introduction to coverage layer testing. For more testing requirements, feel free to call our testing engineers at any time.
.